Features
Key features
IFOV with standard lens (spatial resolution) 0.93 mRad, D:S 1065:1
Detector resolution 640 x 480 (307,200 pixels)
SuperResolution Yes, on camera and in software. Captures and combines 4x the data to create a 1280 x 960 image
MultiSharpâ„¢ Focus Yes, focused near and far, throughout the field of view
LaserSharp® Auto Focus Yes, for consistently in-focus images. Every. Single. Time.
Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen
Advanced manual focus Yes
Touchscreen display (capacitive) 5.7 inch (14.4 cm) landscape 640 x 480 LCD
Rugged, ergonomic design 240 ° rotatable (articulating) lens
Digital zoom 2x, 4x, and 8x
Pre-calibrated Lenses wide angle, 2x telephoto, 4x telephoto and 25 micron/macro
Temperature measurement
Temperature measurement range (not calibrated below -10 °C) -20 °C to 1000 °C (-4 °F to 1832 °F)
Accuracy ±2 °C or 2% (at 25 °C nominal, whichever is greater)
Thermal sensitivity (NETD)* ≤ 0.05 °C at 30 °C target temp (50 mK)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Live line marker Yes
*Best possible